- EBU QC ID
- 0084B
- Name
- Audio Peaks (TP)
- Status
- published
- Category
- absolute
- Lead editor
- Roman Meszmer (ORF)
- Aliases
- true peak TP
- Tags
- audio
| Version | Status | Edition date | Saved by | Note |
|---|
- Definition
- System shall check True Peak levels against a user-defined value.
- CheckResult definition v3
- not in this version
- Analysis method v3
- not in this version
- References
-
-
ATSC A/85
-
ITU-R BS.1770-3
-
- Examples
-
-
00:00:40:20 Audio peak detected, -10dBTP.
-
00:00:56:15 Audio peak detected, -13dBTP.
-
No Organisation has tagged this Item.
What does this mean?| Name | Description |
|---|
| Name | Description |
|---|
| Title | Version | Download |
|---|
- Remarks
-
The max TP level for linear audio in production is -1dBTP (see EBU R 128 and EBU Tech 3343).
Where bitrate compression is used, -3 dBTP may apply (see EBU Tech 3344).
Note that (Q)PPM and true peak are different measurements.
With the introduction of loudness measurement (see 0010B), PPM measurements are being replaced with Loudness and TP measurements.
The (Q)PPM test item is 0085B.
| Title | Author | Last update |
|---|